Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial 

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Special Cables

CALETRUCK M,N

Temperature range:

  • CALETRUCK M: -40°C to +85°C
  • CALETRUCK N: -40°C to +85°C

Test voltage:

  • CALETRUCK M: 2000 V
  • CALETRUCK N: 3000 V

Minimum bending radius:

  • CALETRUCK M: fixed installation 5x cable Ø
  • CALETRUCK N: fixed installation 15x cable Ø

Insulation resistance:

  • CALETRUCK M: min. 20 MOhm x km
  • CALETRUCK N: min. 20 MOhm x km

Nominal voltage:

  • CALETRUCK N: 75 V DC

Properties

  • CALETRUCK M:
  • UV-resistant, largely resistant to oil, weather, and chemicals, self-extinguishing and flame retardant, test method B according to VDE 0472 part 804 and IEC 60332-1
  • Chemical resistance see table Technical Information
  • Polarity easy to determine by a white line on the jacket above the white conductor
  • CALETRUCK N:
  • UV-resistant, largely resistant to oil, weather, and chemicals, self-extinguishing and flame retardant, test method B according to VDE 0472 part 804 and IEC 60332-1
  • Chemical resistance see table Technical Information
  • Complies with GGVS regulations
  • Approved and tested by the TÜV technical inspectorate
  • The additional jacket means that the cable is very robust, and can be installed without a corrugated conduit
  • Installation time is shorter due to twin design
  • Polarity is easy to determine even without stripping thanks to an imprint with the type designation and on the jacket over the positive conductor. This helps prevent wrong connections
  • The special construction of the conductor enables optimal crimping
  • Easy mechanical separation of the jacket web

CALETRUCK M

Conductors x cross-sec. mm² Outer
Diameter
Copper weight
kg/km
Weight
ca. kg/km
AWG
2x1.5 6.8 28.8 90.0 16
2x1.5 6.8 28.8 90.0 16
272 2x1.5 6.8 28.8 90.0 16

CALETRUCK N

Conductors x cross-sec. mm² Outer
Diameter
Copper weight
kg/km
Weight
ca. kg/km
AWG
2x2.5 9.4 48.0 87.0 14
2x4 11.5 77.0 125.0 12
2x6 15.2 116.0 175.0 10
2x10 18.8 192.0 270.0 8
2x16 21.0 308.0 390.0 6
2x25 25.6 480.0 575.0 4
2x35 28.0 672.0 820.0 2
2x50 33.0 960.0 1065.0 1
2x70 36.0 1344.0 1475.0 2/0